Label: Information for the User
balance4.25% glucose, 1.25 mmol/l of calcium, peritoneal dialysis solution
Read this label carefully before starting to use this medication, as it contains important information for you.
dialysisis used to clean the bloodvia the peritoneum in patients with End-stage Chronic Kidney Disease. This type of blood cleaning is known as peritoneal dialysis.
No usebalance4,25% glucose, 1.25 mmol/l of calcium
Do not start peritoneal dialysis if you have:
Warnings and precautions
Inform your doctor immediately:
Peritoneal dialysis may causeprotein lossandwater-soluble vitamin loss.
It is recommended to follow a suitable diet or take dietary supplements to avoid nutritional deficiencies.
Your doctor should check your electrolyte balance, renal function, body weight, and nutritional status.
Due to the high glucose concentration inbalance 4.25% glucose, 1.25 mmol/l of calcium, it should be used with caution and under the supervision of your doctor.
Use ofbalancewith other medications
Inform your doctor or pharmacist if you are using, have used recently, or may need to use any other medication.
Peritoneal dialysis may alter the effect of some medications, so your doctor may need to change the dose for some of them, especially the following:
Your doctor will check your potassium level in the blood and, if necessary, take the necessary measures.
Pregnancy and lactation
If you are pregnant or breastfeeding, or think you may be pregnant, consult your doctor before using this medication. There are no adequate data on the use ofbalancein pregnant women or during lactation.
If you are pregnant or breastfeeding, you should only usebalanceif your doctor considers it absolutely necessary.
Driving and operating machines
The influence ofbalanceon the ability to drive or operate machines is negligible or insignificant.
Follow exactly the administration instructions of this medication as indicated by your doctor. In case of doubt, consult your doctor or pharmacist again.
Your doctor will determine the method, duration, and frequency of use, as well as the required volume of solution and the time of residence in the peritoneal cavity.
If you have tension in the abdominal region, your doctor may reduce the volume.
Continuous Ambulatory Peritoneal Dialysis (CAPD)
The solution is drained after a residence time of between 2 and 10 hours.
The initial recommended dose is 600 – 800 ml/m2of body surface area four times a day (up to 1000 ml/m2at night).
Automated Peritoneal Dialysis (APD)
This system uses thesleeep•safeorSafe•Locksystem. The exchange of bags is controlled automatically by the cycler during the night.
Usebalanceonly in the peritoneal cavity.
Use onlybalanceif the solution is transparent and the container is not damaged.
balanceis available in a double-chambered bag. Before using the solution in the two chambers, mix the solutions as described below.
Instructions for use:
sleeep•safesystemfor Continuous Ambulatory Peritoneal Dialysis (CAPD)
First, warm the bag with the solution to body temperature. This must be done using an appropriate bag warmer. A 2000 ml bag at an initial temperature of 22°C will require 120 minutes of warming time. You can find more detailed information in the instructions for your warmer. To warm the solution, do not use microwave ovens due to the risk of local overheating. The exchange of bags can be carried out after warming the solution.
1. Solution preparation
?Check the bag with the tempered solution (label, expiration date, transparency of the solution, integrity of the bag and overbag, integrity of the weld).?Place the bag on a solid surface.?Open the overbag of the bag and the disinfection cap seal.?Wash your hands with an antimicrobial washing solution.?Roll up the bag, which is placed horizontally on the overbag, from one of the lateral edges until the intermediate weld opens. The solutions from the two chambers are automatically mixed.?Now roll up the bag from the top edge until the lower triangular weld opens completely.?Check that all welds are completely open.?Check that the solution is transparent and that the bag has no leaks.
2. Bag exchange preparation
?Hang the bag with the solution on the upper hanger of the perfusion support, unwind the tubes from the bag with the solution, and place the DISC connector in the organizer. After unwinding the tubes from the drainage bag, hang the said bag on the lower hanger of the perfusion support.?Place the catheter connector in one of the two connections of the organizer.?Put the new disinfection cap on the free connection.?Disinfect your hands and remove the protective cap from the DISC connector.?Connect the catheter connector to the DISC connector.
3. Drainage flow
?Open the extension valve. The drainage flow begins.?
4. Purge
?Once the drainage flow is complete, purge the drainage bag with new liquid (approximately 5 seconds).?
5. Inflow flow
?Start the inflow flow by rotating the rotary switch to the?Position?
6. Safety passage
?Close the catheter extension by introducing the PIN into the catheter connector.?
7. Disconnection
?Remove the protective cap from the new disinfection cap and screw it onto the old one.?Unscrew the catheter connector from the DISC connector and screw it onto the new disinfection cap.
8. DISC connector closure
?Close the DISC connector with the open end of the used disinfection cap, which is placed in the right hole of the organizer.
9.Checkthe transparency and weight of thedialysate drainedand if the effluent is transparent, discard it.
sleeep•safesystemfor Automated Peritoneal Dialysis (APD)
During automated peritoneal dialysis (APD), the cycler warms the solution automatically.
sleeep•safesystemof 3000 ml
3.Remove the protective cap
4.Place the connector in the free port of the traysleeep•safe
5.The bag is ready to use with the equipmentsleeep•safe
sleeep•safesystemof 5000 and 6000 ml
1. Solution preparation
?Check the bag with the solution (label, expiration date, transparency of the solution, integrity of the bag and overbag, integrity of the weld).?Place the bag on a solid surface.?Open the overbag of the bag.?Wash your hands with an antimicrobial washing solution.?Unfold the intermediate weld and the connector of the bag.?Roll up the bag, which is placed horizontally on the overbag, from the diagonal edge towards the bag connector. The intermediate weld will open.?Continue until the small chamber weld also opens.?Check that all welds are completely open.?Check that the solution is transparent and that the bag has no leaks.
2. – 5.:see thesleeep•safesystemof 3000 ml.
Safe•Locksystem for Automated Peritoneal Dialysis (APD)
During automated peritoneal dialysis (APD), the cycler warms the solution automatically.
1. Solution preparation:see thesleeep•safesystemof 5000 and 6000 ml
2. Remove the protective cap from the connector of the connection line.
3. Connect the lines to the bag.
4. Break the internal stop by folding the line and the PIN more than 90° to both sides.
5. The bag is ready for use.
The bags are for single use and any remaining solution without use must be discarded.
After proper training,balancecan be used independently at home. Make sure to follow all the steps you learned during training and maintain the necessary hygiene conditions when exchanging bags.
Always check the turbidity of the dialysate drainage. See section 2.
If you use morebalancethan you should
If you infuse an excess of dialysis solution in the peritoneal cavity, it can be drained. In case of using too many bags, contact your doctor, as it may cause electrolyte and/or fluid imbalance.
In case of overdose or accidental ingestion, consult your doctor or pharmacist or call the Toxicology Information Service, phone 91 562 04 20, indicating the medication and the amount ingested.
If you forgot to usebalance
Try to reach the prescribed total volume for each 24-hour period to avoid consequences that may put your life at risk. You should consult your doctor if you have any doubts.
If you have any other questions about the use of this medication, ask your doctor, pharmacist, or nurse.
It may present the following side effects as a result of peritoneal dialysis treatment in general:
very common (may affect more than 1 in 10 people)
Show your doctor the bag containing the drainage solution.
Contact your doctor immediately if you experience any of these side effects.
Other side effects of treatment are the following:
common (may affect up to 1 in 10 people))
uncommon (may affect up to 1 in 100 people))
very rare(may affect up to 1 in 10,000 people)
not known(the frequency cannot be estimated from the available data)
It may present the following side effects when usingbalance:
very common(may affect more than 1 in 10 people)
common (may affect up to 1 in 10 people))
uncommon (may affect up to 1 in 100 people))
not known(the frequency cannot be estimated from the available data)
Reporting of side effects
If you experience any type of side effect, consult your doctor, pharmacist, or nurse, even if it is a possible side effect that does not appear in this prospectus. You can also report them directly through the Spanish System for Pharmacovigilance of Medicinal Products for Human Use:https://www.notificaram.es. By reporting side effects, you can contribute to providing more information on the safety of this medicine.
Keep this medication out of the sight and reach of children.
Do not use this medication after the expiration date that appears on the bag and on the box after CAD. The expiration date is the last day of the month indicated.
Do not store at a temperature below 4°C.
The ready-to-use solution should be used immediately, within 24 hours after mixing.
Medicines should not be disposed of through drains or in the trash. Ask your pharmacist how to dispose of the containers and medicines you no longer need. This will help protect the environment.
Composition ofbalance
- The active principles in one liter of ready-to-use solutionare
Calcium chloride dihydrate0.1838 g
Sodium chloride5.64 g
Solution of (S)-sodium lactate7.85 g
(3.925 g (S)-sodium lactate)
Magnesium chloride hexahydrate0.1017 g
Glucose monohydrate46.75 g
(42.5 g anhydrous glucose)
These amounts of active substance are equivalent to:
1.25 mmol/l calcium, 134 mmol/l sodium, 0.5 mmol/l magnesium, 100.5 mmol/l chloride, 35 mmol/l lactate, and 235.8 mmol/l glucose.
The other components are water for injection, hydrochloric acid, sodium hydroxide, and sodium bicarbonate.
Appearance of the product and contents of the package
The solution is transparent and colorless.
The theoretical osmolality of the ready-to-use solution is 509 mOsm/l, the pH is approximately 7.0.
balanceis available in double-chamber bags. One chamber contains the alkaline lactate sodium solution and the other chamber contains the acidic glucose solution with electrolytes.
balanceis available in the following application systems and package sizes:
stay•safe: 4 bags of 2000 ml 4 bags of 2500 ml 4 bags of 3000 ml | sleep•safe: 4 bags of 3000 ml 2 bags of 5000 ml 2 bags of 6000 ml | Safe•Lock: 2 bags of 5000 ml 2 bags of 6000 ml |
Only some package sizes may be commercially available.
Marketing Authorization Holder:
Fresenius Medical Care Deutschland GmbH, Else-Kröner-Straße 1, 61352 Bad Homburg v.d.H. Germany
Manufacturer:
Fresenius Medical Care Deutschland GmbH, Frankfurter Straße 6-8, 66606 St. Wendel Germany
Local Representative:
Fresenius Medical Care España S.A.
C/ Ronda de Poniente, 8, ground floor, Parque Empresarial Euronova,
28760 Tres Cantos (Madrid)
Spain
This medicinal product is authorized in the Member States of the European Economic Area with the following names:
See at the end of this multilingual package leaflet.
Last revision date of this package leaflet: 01/2020
The detailed and updated information on this medicinal product is available on the website of the Spanish Agency for Medicines and Medical Devices (AEMPS)http://www.aemps.gob.es/.
Маєте питання щодо цього лікування або ваших симптомів? Зв'яжіться з ліцензованим лікарем для отримання допомоги та персонального догляду.