balance 1.5% with 1.5% glucose and calcium 1.75 mmol/l, peritoneal dialysis solution
Inform your doctor immediately if you experience:
If you are pregnant or breastfeeding, think you may be pregnant, or plan to have a child, consult your doctor before using this medicine. There is not enough data on the use of balance in pregnant and breastfeeding women. During pregnancy or breastfeeding, balance should be used only if the doctor considers it absolutely necessary.
Balance has no influence or negligible influence on the ability to drive and use machines.
In this method, the sleep•safeor Safe •Lock system is used. Bag exchanges are controlled automatically by the cycler throughout the night.
Balance should be used exclusively for intraperitoneal infusions. Balance can only be used when the solution is clear and the bag is undamaged. Balance is supplied in a two-chamber bag. Before use, the solutions from both chambers must be mixed according to the description. During automated peritoneal dialysis (APD), the solution is heated automatically by the cycler.
The bag with the solution should be heated to body temperature first. This is done using an appropriate bag warmer. The warming time for a 2000 ml bag at an initial temperature of 22°C is approximately 120 minutes. More detailed information is contained in the bag warmer's instructions for use. The solution should not be heated using a microwave oven due to the risk of local overheating. After heating the solution, the bag exchange can be started.
Check the heated bag with the solution (label, expiration date, clarity of the solution, no damage to the bag and outer packaging, no damage to the weld line separating the bag chambers). Place the bag on a stable surface. Open the outer packaging of the bag and the packaging of the disinfecting cap. Wash your hands with a bactericidal agent. Roll up the bag lying on the outer packaging, starting from one side, so that the interchamber weld line opens. The solutions from both chambers will mix automatically. Then roll up the bag, starting from the top edge, so that the lower triangle weld line is completely open. Check if all weld lines are completely open. Make sure the solution is clear and the bag does not leak.
Hang the bag on the upper hook of the infusion stand, unfold the bag's drains, and place the DISC connector in the stabilizing base. After unfolding the bag's drains, hang the drain bag on the lower hook of the infusion stand. Insert the patient connector into one of the two holders of the stabilizing base. Insert a new disinfecting cap into the second free holder. Disinfect your hands and remove the protective cap from the disc. Connect the patient connector to the disc.
Open the clamp on the patient connector drain. Drainage begins. Position
After completing the drainage, introduce fresh solution into the drain bag (about 5 seconds). Position
Start introducing the solution by turning the knob to position Position
Close the patient connector drain by inserting a needle plug with a seal (PIN) into the end of the drain. Position
Remove the protective cap from the new disinfecting cap and screw it onto the old one. Unscrew the patient connector from the disc and screw the patient connector onto the new disinfecting cap.
Close the disc with the open end of the used disinfecting cap, which remained in the right holder of the stabilizing base.
System sleep•safefor automated peritoneal dialysis (APD):
During automated peritoneal dialysis (APD), the solution is heated automatically by the cycler.
System sleep•safe3000 ml
Check the bag with the solution (label, expiration date, clarity of the solution, no damage to the bag and outer packaging, no damage to the weld lines separating the bag chambers). Place the bag on a stable surface. Open the outer packaging of the bag. Wash your hands with a bactericidal agent. Unfold the bag with the central weld line and the drain with the bag connector. Roll up the bag lying on the outer packaging, diagonally, towards the end (connector) of the bag. The central weld line will open. Continue until the small chamber weld line opens. Check if all weld lines are completely open. Make sure the solution is clear and the bag does not leak.
System Safe•Lockfor automated peritoneal dialysis (APD):
During automated peritoneal dialysis (APD), the solution is heated automatically by the cycler.
directions by more than 90°.
Each bag should be used only once, and any unused solution should be discarded. After proper training, balance can be used by the patient at home. During bag exchanges, all procedures transmitted during training should be strictly followed, and proper hygiene conditions should be ensured. Always check if the drained dialysate is not cloudy. See point 2.
Using a higher dose of balance than recommended
Excess dialysis solution that has entered the peritoneal cavity can be drained. If too many bags are used, contact your doctor, as fluid and/or electrolyte imbalances may occur.
Missing a dose of balance
Try to take the dose of dialysis solution recommended for each 24-hour period to avoid potentially life-threatening consequences. In case of doubts, consult your doctor. If you have any doubts about using this medicine, consult your doctor, pharmacist, or nurse.
Like all medicines, this medicine can cause side effects, although not everybody gets them. The following side effects may occur as a result of peritoneal dialysis:
very common(may affect more than 1 in 10 people):
uncommon(may affect up to 1 in 100 people):
During the use of balance, the following side effects may occur:
very common(may affect more than 1 in 10 people):
common(may affect up to 1 in 10 people):
If you experience any side effects, including any not listed in this leaflet, inform your doctor, pharmacist, or nurse. Side effects can be reported directly to the Department of Monitoring of Adverse Reactions to Medicinal Products of the Office for Registration of Medicinal Products, Medical Devices, and Biocidal Products:
Al. Jerozolimskie 181 C, PL-02-222 Warsaw, tel: +48 22 49 21 301, fax: +48 22 49 21 309, e-mail:
ndl@urpl.gov.pl.
By reporting side effects, you can help provide more information on the safety of this medicine.
What balance contains
Active substancescontained in 1 liter of balance solution ready for use are:
Calcium chloride dihydrate 0.2573 g
Sodium chloride 5.640 g
Sodium (S)-lactate solution 7.85 g
(3.925 g sodium (S)-lactate)
Magnesium chloride hexahydrate 0.1017 g
Glucose monohydrate 16.5 g
(15.0 g glucose anhydrous)
These amounts of active substances correspond to:
1.75 mmol/l calcium, 134 mmol/l sodium, 0.5 mmol/l magnesium, 101.5 mmol/l chloride, 35 mmol/l lactate, and 83.2 mmol/l glucose
Other components of balance are: water for injections, hydrochloric acid, sodium hydroxide, sodium bicarbonate.
What balance looks like and what the packaging contains
The solution is clear and colorless.
The theoretical osmolality of the prepared solution is 358 mOsm/l, pH around 7.0.
Balance is supplied in a two-chamber bag. One chamber contains a basic sodium lactate solution, and the other contains an acidic electrolyte and glucose solution.
Balance is available in the following application systems (bag volumes and numbers in cardboard boxes are indicated):
stay•safesleep•safeSafe•Lock
4 x 2000 ml
4 x 3000 ml
2 x 5000 ml
4 x 2500 ml
2 x 5000 ml
2 x 6000 ml
4 x 3000 ml
2 x 6000 ml
Not all types of packaging may be available.
Fresenius Medical Care Deutschland GmbH, Else-Kröner-Straße 1, 61352 Bad Homburg v.d.H., Germany
Fresenius Medical Care Deutschland GmbH,
Frankfurter Strasse 6-8,
66606 St. Wendel, Germany
Fresenius Medical Care Polska S.A.,
tel.: +48 61 83 92 600
see the last page of this multilingual packaging leaflet.
06/2019
Need help understanding this medicine or your symptoms? Online doctors can answer your questions and offer guidance.